The following is the procedures of Negative resistance measurement method:
1.Open the crystal output side pin in the circuit used , and connect a precision variable resistor in series with the crystal, as shows the following:  | Rs: The value of the crystal's ESR. VR: Precision variable resistor. Oscilloscope: Must use active probe |
2.Adjusting the VR to start oscillation. 3.Increaseing the VR until oscillation stop. 4.Measuring the VR value. 5.Calculating the -R using in sum of the RS and VR, as shows the following equation: -R=-(Rs+VR) 6.It is preferable to -R, usually, -R>=-(5~10)xRs So the limit of the crystal's ESR can depend on the equation to design.
*The circuit noise will affect the test result. |